Manufacturer: Kalstein
Precision laboratory conductivity meter, 3 points calibration, setup menu contains 7 options. The meter is suitable for measuring the conductivity and TDS, accuracy: 1% F.S.
• Precision laboratory conductivity meter is equipped with a backlit LCD display.
• 1 to 3 points calibration with automatic recognition for conductivity standards.
• Selectable cell constant, temperature coefficient and TDS factor.
• Automatic temperature compensation corrects conductivity measurment to reference
temperature.
• Auto-Read function senses and locks the measurement endpoint.
• Setup menu allows setting the number of calibration points, temperature unit, etc.
• Reset function automatically resumes all settings back to the factory defaults.
• Water quality analysis
• Research and educations
• Environmental monitoring and other industrial applications
Model | YR01830 |
Conductivity | |
Range | 0.01 to 20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
Resolution | 0.001, 0.01, 0.1, 1 |
Accuracy | ±1% F.S. |
Calibration Points | 1 to 3 points |
Calibration Solutions | 10µS, 84µS, 1413µS, 12.88mS, 111.8mS |
TDS | |
Range | 0 to 10.00, 100.0, 1000ppm, 10.00, 200.0ppt |
Resolution | 0.01, 0.1, 1 |
Accuracy | ±1% F.S. |
TDS Factor | 0.1 to 1.0 (default 0.5) |
Temperature | |
Range | 0 to 105°C/32 to 221°F |
Resolution | 0.1°C/0.1°F |
Accuracy | ±1°C/±1.8°F |
Offset Calibration | 1 point |
Calibration Range | Reading ±10°C |
General Specifications | |
Temperature Compensation | 0 to 100°C/32 to 212°F, manual or automatic |
Temperature Coefficient | Linear (0.0 to 10.0%/°C) |
Reference Temperature | 25°C |
Cell Constant | K=0.1, 1, 10 or custom |
Hold Function | Manual or auto-endpoint |
Connector | 6-pin nimi-DIN, 3.5mm jack socket |
Display | Custom LCD (120×60mm) |
Power | DC9V, using AC adapter, 220V/50Hz |
Dimensions | 210(L)×205(W)×75(H)mm |
Weight | 1.5kg |
Order Code | Accessories |
YR01830 | CON-1 conductivity electrode |
TP-10K temperature probe | |
Conductivity standards 84µS/cm, 1413µS/cm, 12.88mS/cm | |
DC9V power adapter | |
YR01830-2
|
CON-0.1 conductivity electrode |
CON-1 conductivity electrode | |
TP-10K temperature probe | |
Conductivity standards 84µS/cm, 1413µS/cm, 12.88mS/cm | |
DC9V power adapter | |
YR01830-1 | CON-1 conductivity electrode |
CON-10 conductivity electrode | |
TP-10K temperature probe | |
Conductivity standards 84µS/cm, 1413µS/cm, 12.88mS/cm | |
DC9V power adapter |
Weight | 1,5 kg |
---|---|
Dimensions | 32 × 27 × 20 cm |
Modelo | YR01830, YR01830-1, YR01830-2 |